OTA API ​

Firmware updates are uploaded over plain HTTP on port 80. This replaces ArduinoOTA, which uses a raw UDP/TCP protocol that browsers cannot speak.

POST /api/ota ​

Send one firmware .bin as multipart/form-data with the field name firmware.

http
POST /api/ota
Content-Type: multipart/form-data; boundary=...
x-fw-size: 1048576
x-md5: d41d8cd98f00b204e9800998ecf8427e

--...
Content-Disposition: form-data; name="firmware"; filename="firmware.bin"
Content-Type: application/octet-stream

<binary>
--...--

Headers ​

HeaderRequiredDescription
x-fw-sizenoFirmware size in bytes. Passed to Update.begin(size) so excess or short transfers are rejected up front.
x-md5no32-character hex MD5 of the firmware. When present, verified after the transfer. This detects corruption, not tampering.

Responses ​

StatusBodyDescription
200{"ok":true}Update accepted; the device restarts in about one second.
400{"error":"ota busy"}Another update is already in progress.
400{"error":"no filename"}The multipart part has no filename.
400{"error":"<Update.errorString()>"}Flashing failed; the message comes from the update library.

The 200 response is sent before the restart is scheduled, so the client receives it before the connection drops.

Browser Example ​

js
async function uploadFirmware(file) {
  const body = new FormData();
  body.append("firmware", file);

  const xhr = new XMLHttpRequest();
  xhr.open("POST", "/api/ota");
  xhr.setRequestHeader("x-fw-size", file.size);
  xhr.upload.onprogress = (e) => {
    if (e.lengthComputable) console.log(`${(e.loaded / e.total) * 100}%`);
  };
  xhr.onload = () => console.log(xhr.status, xhr.responseText);
  xhr.send(body);
}

Behavior ​

  • The image is always written to U_FLASH; filesystem images are never accepted, so /config cannot be overwritten.
  • The multipart body is streamed to Update.write() chunk by chunk; the full firmware is never buffered in RAM.
  • Background provider and system tasks are suspended while flash is being written.
  • Only one update runs at a time; a second request returns ota busy.

Security ​

This endpoint has no authentication or authorization, by design for a home or local AP network. Anyone who can reach the device can flash it. Do not expose the device to an untrusted network.